Advanced Heat Pump Controller - HBX ECO-0600

Order online

Or call us for a complete-system quote and volume pricing.

$640.43 $576.38
Shipping $122 Free

Secure checkout · Free shipping

  • SensorLinx remote accessMonitor the controller remotely with app access and alarm email notifications.
  • Outdoor reset controlManages geothermal heating and cooling around outdoor temperature conditions.
  • Up to 4 stages plus backupControls four heat pump stages and a backup boiler per module.
  • Single or dual tank setupSupports one tank or separate hot and cold tank applications.
  • Expandable to 16 stagesLink ECO-0600 modules wirelessly for larger staged systems.

Product details

Advanced Heat Pump Controller - HBX ECO-0600

Advanced geothermal and hydronic heat pump controller designed to manage multi-stage heating and cooling systems, backup heat, domestic hot water, pumps, and outdoor reset control from one intelligent module.

 

Key Benefits

  • Controls up to 4 heat pump stages from one controller
  • Expandable up to 16 total stages with additional ECO-0600 modules
  • Supports single tank or dual hot/cold tank applications
  • Manages backup heat, DHW, reversing valve, and pump outputs
  • Outdoor reset with WWSD and CWSD options for efficient operation
  • Wi-Fi enabled for remote monitoring and control through the SensorLinx app

 

Specifications

  • Power Supply: 120VAC, 50/60Hz
  • Heat Pump Stages: Up to 4 stages per controller
  • Expandable Staging: Up to 16 total stages
  • Applications: Geothermal, hydronic heating, cooling, DHW, backup heat
  • Tank Control: Single tank or dual hot/cold tank setup
  • Communication: HBX Wi-Fi and HBX wireless controller communication
  • Wi-Fi: 2.4GHz network only
  • Sensors: Outdoor sensor, tank sensors, DHW sensor support
  • Dimensions: 5.16" W x 9.83" H x 2.64" D
  • Listings: ETL listed, meets CSA C22.2 No. 24 and UL Standard 873

Independent feedback

Customer Reviews

Company trust comes first, followed by detailed reviews for this product.

Verified company reviews

Reviews for Advanced Heat Pump Controller - HBX ECO-0600

HBX ECO-0600

Advanced Heat Pump Controller

  1. Geothermal outdoor reset control

    Designed as a stand-alone outdoor reset controller for geothermal hydronic heating and cooling applications.

  2. Up to four stages plus backup

    Controls up to four heat pump stages and a backup boiler per module for staged heating or cooling operation.

  3. Expandable staged systems

    Additional ECO-0600 modules can link wirelessly for sequential control of up to 16 total heat pump stages.

  4. SensorLinx remote access

    Wi-Fi enabled for remote monitoring through the SensorLinx mobile app on Apple iOS and Android devices, with alarm email notifications.

  5. DHW priority control

    Supports domestic hot water control with automatic DHW priority over heating and cooling calls when enabled.

  6. Automatic system management

    Includes WWSD/CWSD options, auto-changeover, heat or cool priority setup, pump post purge, and exercising options.

HBX ECO-0600 geothermal controller application overview
HBX ECO-0600 geothermal controller

Smart connectivity

Use SensorLinx to view controller status remotely, receive alarm email notifications, and monitor connected heating or cooling equipment.

Flexible staging

Configure one to four heat pump stages, add backup heat, and rotate heat pumps based on run time or cycles.

Advanced system management

Outdoor temperature reset, warm weather shutdown, cold weather shutdown, auto-changeover, and priority logic help match system operation to real conditions.

Integrated backup heat

The backup boiler can activate from outdoor temperature, tank temperature differential, or a programmed delay after heat pump staging.

Installed in real homes and workshops

Customer Success Stories

See how customers use MBTEK products in real projects.

Technical specifications

Manual-backed technical data for the HBX ECO-0600 geothermal control.

Product family HBX ECO-0600 geothermal control
Application Geothermal outdoor reset control for hydronic heating and cooling
Inputs 4 thermistor inputs, 10k Ohm
Stage relays 4 stage relays, 24VAC, 2A max
AUX relays 3 AUX relays: 120VAC 1/6hp FLA or LRA 5A max pump; 240VAC 1/2hp FLA or LRA 5A max pump; 120/240VAC 5A max other
Input power 120VAC +/- 10%, 50/60Hz, 250mA max; combined relay power should not exceed 15A
Dimensions and weight 131mm W x 246mm H x 66.71mm; 0.750kg
Listings and network CSA C22.2 No. 24, UL 873, ETL control no. 3068143; 2.4GHz Wi-Fi only

Refer to the installation manual for wiring diagrams, setup options, safety warnings, troubleshooting, and warranty details.

Product documents

Installation, wiring, setup, application drawings, troubleshooting, and warranty information for the ECO-0600.

ECO-0600 Installation Manual

Installation, wiring, setup, application drawings, troubleshooting, and warranty information.

Need an installer?
We made it easy for you.

Find an installer

Please note that listed installers are independent contractors and not employees of MBTek. They are skilled professionals familiar with our products and capable of efficient installation.

Any questions?
Reach out to us

Our team can help with product questions, sizing guidance, and next steps.

Contact us
Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Promotion
Call now 1-888-301-0737