Best for radiant floors & fan coils
Designed for efficient hydronic heating and cooling.
Track orders, manage your details, and sign in without a password.
APOLLO cold-climate series
72,000 BTU EVI Inverter · 4,000 to 6,000 ft²
A high-capacity 6 ton heat pump for hydronic heating, cooling, domestic hot water, and pool heating in large homes and light-commercial projects.
You could get a better price by calling us for a complete system.
One outdoor unit, many applications
The 6 Ton Air-to-Water Heat Pump is designed for radiant floors, fan coils, and air handlers, providing efficient heating, cooling, and domestic hot water from one cold-climate system.
Designed for efficient hydronic heating and cooling.
One outdoor unit can support year-round home comfort.
Built for demanding winter climates.
COP up to 5.65 helps reduce energy consumption.
Inverter output adjusts gradually instead of hard cycling.
More than an outdoor unit
Tell us about your home, existing heating system, and comfort goals. MBTEK helps match the heat pump with compatible indoor equipment, tanks, pumps, controls, and accessories.
Independent feedback
Company trust comes first, followed by detailed reviews for this heat pump.
Convinced by the results?
Jump back to pricing, pick your property size, and add it to your cart.
Product FAQ
Direct answers about 6 ton heat pump capacity, sizing, cold-weather performance, hydronic applications, efficiency, and installation planning.
The APOLLO 6 ton heat pump is sold in the 72,000 BTU nominal capacity class. Heat pump tonnage describes heating and cooling capacity, not the unit's physical weight. This is an air-to-water hydronic heat pump, not a conventional ducted air conditioner or condenser. Actual output changes with outdoor temperature and leaving-water temperature.
The general planning range for this 6 ton heat pump is 4,000 to 6,000 ft². This is a starting point, not a substitute for load calculations. Climate, insulation, windows, ceiling height, air leakage, required water temperature, and indoor distribution all affect the capacity a building needs.
The APOLLO 6 ton heat pump can serve large residential and light-commercial hydronic projects. Its general planning range is 4,000 to 6,000 ft², subject to load calculations. Larger buildings or higher loads may require multiple heat pumps or staged capacity.
Compare the building's design heating and cooling loads with the 6 ton heat pump output at the local design temperature and required leaving-water temperature. The system design should also account for radiant floors, fan coils, air handlers, zones, domestic hot water, pool heating, and any backup or staged heat source.
Yes. The APOLLO can supply heated water to radiant floors, fan coils, or compatible air handlers. For cooling, it supplies chilled water to fan coils or air handlers designed for cooling and dehumidification. Radiant-floor cooling requires dew-point and condensation controls and should only be used in a properly engineered system.
The APOLLO operating range extends from -31°F to 110°F, but operating range does not mean full output remains available at every temperature. At the manual's 10°F heating test condition, this model produces approximately 39.2 KBTU with a COP of 2.11. Compare condition-specific output with the building load to determine whether backup or staged capacity is needed.
It can serve as the main hydronic heat source when its condition-specific output and maximum leaving-water temperature of Up to 131°F match the building and its emitters. Radiant floors and other low-temperature systems are strong applications. High-temperature radiators or baseboards must be checked carefully before replacing a boiler.
Yes, when paired with the correct indirect domestic-hot-water tank, pool heat exchanger, piping, and controls. The outdoor heat pump does not provide tankless domestic hot water by itself. Tank recovery, system priority, pool load, and simultaneous space-heating demands must be included in the system design.
A complete hydronic system may include a Hydro Station, indirect domestic-hot-water tank, buffer tank, circulators, controls, expansion equipment, air and dirt separation, electrical protection, and radiant, fan-coil, or air-handler distribution. The exact bill of materials depends on the application and piping layout.
Published performance reaches a COP of up to 5.65 under favorable test conditions, but that is not a year-round guarantee. COP changes with outdoor temperature, water temperature, load, flow, and system design. Use the condition-specific performance tables when estimating operating efficiency.
The product price shown on this page covers the selected equipment configuration, not necessarily a complete installed hydronic system. Total project cost depends on tanks, controls, indoor distribution, electrical work, piping, labor, and project complexity. A system plan is needed for a meaningful installed-cost estimate.
This model uses 220–240V / 1 / 60Hz power and has a published sound level of 58 dB(A). Its rated water flow is 19.2 GPM through a 1 1/4 in water connection. Electrical protection, piping, clearances, freeze protection, startup, and local-code requirements must be confirmed from the current installation manual by qualified professionals.
Current model
72,000 BTU / 6 Ton · 4,000 to 6,000 ft². Homes from 4,000 to 6,000 ft² and light-commercial hydronic applications.
Property-size ranges are planning guides only. Final model selection requires a heat-loss or load calculation that accounts for climate, insulation, air leakage, windows, water temperature, and system application. Actual output changes with outdoor air and leaving-water temperature.
| Specification | 6 Ton |
|---|---|
| Property-size guide | 4,000 to 6,000 ft² |
| Rated heating capacity | 83.5 KBTU |
| Rated cooling capacity | 68.9 KBTU |
| Ambient operating range | -31°F to 110°F |
| Maximum leaving-water temperature | Up to 131°F |
| Power supply | 220–240V / 1 / 60Hz |
| Sound level | 58 dB(A) |
| Rated water flow | 19.2 GPM |
| Water connection | 1 1/4 in |
| Refrigerant / charge | R-32 / 134.6 oz |
| Dimensions L × W × H | 47.6 × 20.9 × 57.3 in |
| Weight | 403.5 lb |
| Measurement | 6 Ton |
|---|---|
| Capacity | 71.5 KBTU |
| Input power | 15.7 kW |
| Current | 20.8 A |
| COP | 4.6 |
| Measurement | 6 Ton |
|---|---|
| Capacity | 56.3 KBTU |
| Input power | 17 kW |
| Current | 22.7 A |
| COP | 3.38 |
| Measurement | 6 Ton |
|---|---|
| Capacity | 39.2 KBTU |
| Input power | 18.6 kW |
| Current | 24.8 A |
| COP | 2.11 |
| Measurement | 6 Ton |
|---|---|
| Capacity | 51.2 KBTU |
| Input power | 20.4 kW |
| Current | 27.2 A |
| COP | 4.6 |
| Electrical measurement | 6 Ton |
|---|---|
| Fan motor load | 0.58 A |
| Compressor rotor load | 37.47 A |
| Total load | 38.05 A |
| Minimum circuit ampacity | 58.72 A |
| Maximum overcurrent protection | 100.78 A |
Electrical design and overcurrent protection must be confirmed by a qualified professional against the current manual and local code.
Plan with the right documents
Keep the technical source documents visible before equipment selection and installation.
Installation, startup, servicing, performance, electrical, and maintenance guidance for the standard APOLLO air-to-water range.
Open manual PDFCompliance and certification documentation for the APOLLO air-to-water heat pump family.
Open certification PDFFor US customers
Federal, state, utility, and local programs can depend on location, equipment eligibility, installer requirements, and system configuration.
Confirm eligibility with your installer, utility, and program administrator before purchase. MBTEK cannot guarantee eligibility, approval, or claim administration.
Need a complete answer?
A short call can prevent mismatched temperatures, missing components, and incorrect capacity assumptions.