icon
Affiliate Program

BUY ANY 3 ITEMS, GET 30% OFF Free Shipping

APOLLO Commercial Air Handling Unit 25 Ton

Works seamlessly with our Apollo heat pumps

Select your AHU size

Order online

Or call us for a complete-system quote and volume pricing.

30% OFF $12,484 $8,739
Shipping $2,122 Free

Secure checkout · Free shipping

  • All-in-One Climate ControlHeats, cools, humidifies, and dehumidifies centrally.
  • Hydronic AHU SystemEngineered for seamless central duct ventilation.
  • Integrated Free CoolingEvaporative cooling pad maximizes energy savings.
  • Built-in Backup SystemsReliable backup heater and automatic water feed included.
  • Flexible Flow OptionsAvailable in standard upflow or custom downflow.

Frequently Bought Together

APOLLO Commercial Air Handling Unit 25 Ton

APOLLO Commercial Air Handling Unit 25 Ton

Total price: $12,484

APOLLO Central Air Handling AHU

Main Features

  1. Efficiency Redefined

    Delivers optimal airflow and temperature control to reduce wasted energy and improve whole-home comfort.

  2. Versatile Functionality

    Handles heating, cooling, humidifying, and dehumidifying in one centralized AHU platform.

  3. Silent and Powerful

    Uses high-efficiency fan motors to provide strong performance with quieter day-to-day operation.

  4. Powerful Integrations

    Designed for seamless use with APOLLO heat pumps and the APOLLO 24VAC FCU thermostat.

  5. User-Focused Monitoring

    Supports streamlined monitoring and control for easier indoor climate management and system visibility.

  6. Hydronic Duct Solution

    Engineered as a central duct AHU for residential and commercial applications where stable temperature and humidity matter.

APOLLO Central Air Handling AHU feature overview
APOLLO Central Air Handling AHU control integration image

Efficient Climate Control

The APOLLO Central Air Handling AHU combines optimized airflow and stable temperature control to improve comfort while supporting lower energy waste.

Versatile Functionality

This AHU supports heating, cooling, humidifying, and dehumidifying so one system can serve a broader range of indoor climate demands.

Silent and Powerful Performance

A high-efficiency fan motor provides strong air movement and improved comfort without the noise expected from larger centralized equipment.

Seamless Integration & Smart Control

Pair the AHU with APOLLO heat pumps and the APOLLO 24VAC FCU thermostat for simpler setup and more precise indoor climate control.

Installed in real homes and workshops

Customer Success Stories

See how customers use MBTEK products in real projects.

Technical specifications

Specifications for the APOLLO Commercial Air Handling Unit 25 Ton.

Model / SKU AP-COMM-AHU-25T
Capacity 25 Ton
System type Commercial hydronic air handling unit
Application Commercial and large commercial ducted systems
Functions Heat, cool, humidify, dehumidify, backup heater, evaporative cooling
Cooling feature Integrated evaporative cooling pad with automatic water feed
Fan / performance High-efficiency fan motors for powerful commercial airflow
Installation advantage Designed to replace outdated central duct systems
Availability Special order
Compatibility APOLLO Air to Water Heat Pump

Product documents

No product documents or manuals are currently published here. Contact us if you need technical documentation.

Product details

CENTRAL AIR HANDLING UNIT - 25 TON (APOLLO AHU)

High-performance commercial hydronic air handling unit designed for large commercial duct systems, delivering high-capacity heating, cooling, and indoor comfort control with quiet operation and seamless APOLLO heat pump integration.

Key Benefits

  • Commercial and large commercial AHU for central ducted hydronic systems
  • Designed to replace or upgrade outdated duct systems for improved comfort and efficiency
  • High-capacity airflow helps reduce hot and cold spots across larger conditioned spaces
  • Integrated comfort functions for heating, cooling, humidification, dehumidification, backup heating, and evaporative cooling
  • Quiet operation with high-efficiency fan motors for powerful commercial airflow
  • Designed for use with APOLLO air-to-water heat pump systems

Specifications

  • Capacity: 25 Ton
  • System Type: Commercial hydronic air handling unit
  • Application: Commercial and large commercial ducted systems
  • Functions: Heat / Cool / Humidify / Dehumidify / Backup Heater / Evaporative Cooling
  • Cooling Feature: Integrated evaporative cooling pad with automatic water feed
  • Installation Advantage: Designed to replace outdated central duct systems
  • Compatibility: APOLLO air-to-water heat pump systems

Air Handling Unit FAQ

APOLLO Central Air Handling Unit — Frequently Asked Questions

Answers about sizing, capacities, electrical and water requirements, controls, and installation for the APOLLO Central AHU 3.5, 6, and 25 Ton models.

What size APOLLO air handling unit do I need — 3.5, 6, or 25 Ton?

The 3.5 Ton (1,400 CFM) suits most residential and light commercial ducted systems. The 6 Ton (2,400 CFM) is for larger homes and light commercial spaces and adds humidification, dehumidification, backup heating, and evaporative cooling. The 25 Ton is a commercial unit for large commercial buildings. Correct sizing depends on square footage, insulation, layout, climate, and heat loss, so confirm the load before ordering — use the model selector above to switch between sizes.

What are the airflow and coil capacities of each model?

The 3.5 Ton delivers 1,400 CFM nominal airflow with a hydronic coil (22 × 22 × 5 in) rated up to 193,600 BTU. The 6 Ton delivers 2,400 CFM at 2.0 in. w.g. rated external static pressure with a larger coil (20 × 32 × 6 in) rated up to 460,000 BTU. Actual output depends on the entering water temperature from your heat pump — higher supply temperatures increase heating output.

What electrical supply and breaker does each model need?

The 3.5 Ton and 6 Ton both run on a 220V, 60 Hz supply. The 3.5 Ton requires a 15A breaker and the 6 Ton requires a 60A breaker. Confirm wire gauge and breaker sizing against the product manual and your local electrical code before installation.

What are the water connection and flow-rate requirements?

Both the 3.5 Ton and 6 Ton use 1 in. FPT female pipe thread connections for supply and return. The recommended minimum flow rate is 17.6 GPM for the 3.5 Ton and 21.2 GPM for the 6 Ton. Fit shut-off valves and an air vent at each connection, and insulate the supply line to prevent surface condensation during cooling.

Is the APOLLO AHU compatible with an air-to-water heat pump?

Yes. Every APOLLO Central AHU is a hydronic unit designed for the APOLLO Air to Water Heat Pump. The heat pump produces hot water for heating and chilled water for cooling, and the AHU uses that water at its coil to condition the air it distributes through your ducts. The same water loop can also serve fan coils, radiant floors, or domestic hot water.

What thermostat and controls does the AHU use?

The APOLLO Central AHU is designed for smart thermostat control and pairs with the APOLLO 24VAC FCU thermostat, available as an add-on with each model above. The thermostat manages heating and cooling changeover and fan operation based on the water temperature supplied by the heat pump.

Which functions does each model provide?

All three models heat and cool from the same hydronic coil. The 6 Ton and 25 Ton models add humidification, dehumidification, backup heating, and integrated evaporative cooling with an automatic water feed for free or backup cooling. The 3.5 Ton focuses on efficient heating and cooling for smaller ducted systems.

What is upflow vs downflow, and is sideflow available?

Upflow and downflow describe the direction the unit moves air. An upflow unit pulls air in low and discharges out the top (typical for basement or closet installs with ducts overhead); a downflow unit discharges out the bottom (used when ducts run below, such as an attic). The 3.5 Ton and 6 Ton ship upflow as standard, with downflow and sideflow available as special order to match your duct layout.

Can the AHU replace my existing central duct system?

Yes. The APOLLO Central AHU is designed to replace or upgrade an outdated central duct system. It reuses your existing ductwork while improving airflow, temperature control, and indoor air quality, and it swaps refrigerant-based equipment for a hydronic system driven by the APOLLO Air to Water Heat Pump. The 25 Ton commercial model is built specifically to modernize legacy large-building duct infrastructure.

What air filters does the AHU use and how do I maintain it?

The 3.5 Ton uses a 24 × 24 × 1 in. MERV 8 pleated filter and the 6 Ton uses a 20 × 24 × 2 in. MERV 8 pleated filter (each supplied as a 2-pack). Replace or clean the filter on a regular schedule, keep supply and return grilles clear, inspect the coil and condensate drain periodically, and check the evaporative cooling pad and its automatic water feed on models that include it. A hydronic AHU has no indoor refrigerant circuit to service.

Independent feedback

Customer Reviews

Company trust comes first, followed by detailed reviews for this product.

Verified company reviews

Reviews for APOLLO Commercial Air Handling Unit 25 Ton

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.